Kerrison Rongeurs by Symmetry supplied by Obex

  • Feb 19, 2021
  • 2 min read

Hi all I received an interesting email with photos this morning regarding the above RMD. The manager of the CSSD concerned had been presented with the item but no MIFU. They queried the MIFU with Obex and was given a set of generic instructions but no specific instructions. They were also told that many DHB's in NZ are using this product without issue. That in itself is an issue and a statement often bandied around by reps to get out of a situation. Fortunately this CSSD manager after having used the product a couple of times dismantled the item after cleaning as per the instructions  to find it was full of debris from the patients. So what can they do. *Show the photos to the surgeon so that they can see they are compromising patient care. *Add this item to their DHB's risk register *Advise the supplier that they must provide validated cleaning instructions for that specific instrument or have it returned a and replaced with one that can be dismantled. *Complete event forms that require open disclosure to the patient regarding the fact that the instruments are not as clean as they should be. No RMD should be purchased without the prior approval from CSSD leader re suitability for cleaning. AS/NZS4187:2014: 2.4.2 Purchasing states: section(b): Involvement of the reprocessing facility manager in the selection process prior to the purchase of an RMD section(c): Evaluation to ensure compatability with the reprocessing systems available for use in the reprocessing facility. section(g): Provision of documented and validated reprocessing instructions in accordance with ISO17664 for RMD's (including trial and loan RMD's)rongeur 1       rongeur 2 If any of you are using the above rongeurs please contact me as I would like to know how you are guaranteeing that they are clean on the inside. This may be helpful to others. regards Shelagh Thomas

 
 
 

Recent Posts

See All
Membership site

Kia ora, Our new website is live but we are still refining management of the membership side of things. As advised in the February Supplyline Journal, your membership login is not able to be transferr

 
 
 
Know Your Standards part 2

Did you know that surgical instruments should come back to CSSD relatively clean and not look like a bloodbath on a trolley. Did you...

 
 
 
Know your Standards-Part1

How many of you can actually say you are familiar with the standard AS5369 and what is actually written inside it. Did you know that in...

 
 
 

Comments


Subscribe to our newsletter

bottom of page